Comprehensive assessment of tranexamic acid during orthognathic surgery: A systematic review and meta-analysis of randomized, controlled trials.

Affiliation

School of Stomatology, Shandong University, 250012, Jinan City, Shandong Province, PR China; Department of Oral and Maxillofacial Surgery, School of Stomatology, Shandong University, Jinan City, Shandong Province, PR China. Electronic address: [Email]

Abstract

The objective of this study was to comprehensively assess the use of tranexamic acid (TXA) during orthognathic surgery. A systematic review and meta-analysis of randomized controlled trials addressing these issues were carried out. Three electronic databases, included PubMed, Web of Science, and Cochrane Library, were searched until April 30, 2018. Eligible studies were restricted to randomized, controlled trials (RCTs). Weighted mean differences (WMD) for blood loss, operation time, haematocrit, quality of surgical field, and odds ratio (OR) for transfusion rates were pooled for the included studies. Eight randomized, controlled trials were included for analysis. Compared with the control group, the TXA group showed a reduction in intraoperative blood loss of 165.03 ml (p < 0.00001; 95% CI, -200.93 to -129.13 ml), a reduction in the drop of haematocrit of 2.32 g/dl (p < 0.00001; 95% CI, -3.38 to -1.26 g/dl), and an improved quality of surgical field (p < 0.00001; MD, -1.01; 95% CI, -1.23 to -0.80). Tranexamic acid has a limited effect on reducing operative time (p < 0.00001; MD, -16.18 min; 95% CI, -19.60 to -12.75 min) and on decreasing the transfusion rates (p = 0.02; OR = 0.33; 95% CI, 0.13 to 0.83).

Keywords

Blood loss,Haematocrit,Operation time,Orthognathic surgery,Quality of surgical field,Tranexamic acid (TXA),